    All defectsWATERPROOFING · BATHROOM

    Broken waterstop, or membrane stopping short of it

    76% of homes had at least one bathroom, wet-area or tiling defect at handover.

    Broken waterstop, or membrane stopping short of it
    Found at a recent handover inspection.

    What it is

    The metal angle at a bathroom doorway that keeps water in the bathroom is broken, or the membrane under it doesn't run up the angle.

    Why it matters

    Shower water can track under the door into the bedroom carpet and floor. Once it's tiled, nobody can see the membrane.

    How we check it

    At waterproofing stage we check the membrane runs up the water stop angle. At handover we check the angle is intact.

    The fix

    At waterproofing stage it's a quick fix. After tiling, tiles have to come up.

    How common it is

    76% of homes had at least one bathroom, wet-area or tiling defect at handover.

    What this means for your home

    The waterstop angle and the membrane at a shower threshold are the last line of defence that keeps water inside the wet area, and a defect here — a membrane that stops short, a waterstop set too low, a pinhole at a corner — is only fixable before the tiles go on. AS 3740 sets how the membrane and waterstop are formed at the door and penetrations. That makes the waterproofing stage the one chance to catch it; after tiling, a leak means lifting the floor to re-do the lot. Caught at the right stage it is the waterproofer coming back before the tiler. We inspect the membrane at every corner, penetration and threshold, check the waterstop height against the finished floor, and photograph any gap, thin spot or short membrane so the wet area is sound before it is sealed in. We photograph the membrane and waterstop at every threshold and corner so the waterproofer addresses it before the tiler arrives. This is the clearest example of why the stage matters: after the tiles go on, a membrane fault means demolishing a finished bathroom to reach it. An inspection at the waterproofing stage is the single most cost-effective check in the whole build for exactly this reason.

    The standard

    AS 3740-2021, Figure 4.9.1(C)