What it is
The sill of an external sliding door sits level or slopes back toward the house.
Why it matters
Rain ponds on the sill and can get under the frame into the floor.
How we check it
We put a level on external door sills to check they fall away from the house.
The fix
Re-set the sill so water drains outward.
How common it is
70% of the homes we inspected at handover had at least one door or window defect.
What this means for your home
An external door sill should shed water away from the house; one that falls back toward the floor funnels every shower of wind-driven rain straight under the door. The NCC and the QBCC guide require thresholds and the ground outside to drain away from the building. Caught at handover it is a packing or flashing fix at the one door; lived with, it is water across your floor every storm, swollen door jambs and, eventually, a rot problem in the frame behind the lining. It is an easy thing to miss because it only reveals itself in heavy rain. We put a level across every external threshold and check the fall of the paving or ground immediately outside, so a sill that drains the wrong way is corrected before the first big Queensland downpour tests it. The report shows the level reading and the direction of fall so the builder cannot argue the threshold is fine. A sill that drains the wrong way only announces itself in the next big storm, by which time the water is already inside — so catching it with a spirit level on a dry handover day, while the fix is still simple packing or flashing, is precisely the point of an independent check.