    Gaps at fascias, soffits and cladding

    Nearly 1 in 3 new homes we inspected (30%) had gaps that let pests in. Unsealed fascia, soffit or cladding junctions turned up in 35%.

    Gaps at fascias, soffits and cladding
    Found at a recent handover inspection.

    What it is

    Open gaps where the fascia, soffit or wall cladding meet, or under the bottom cladding board.

    Why it matters

    An open door for rodents and insects, and wind-driven rain can get in behind the cladding.

    How we check it

    Many of these gaps can't be seen from the ground, so we check them with an inspection mirror.

    The fix

    Seal with a suitable flexible sealant or fit the correct trim.

    How common it is

    Nearly 1 in 3 new homes we inspected (30%) had gaps that let pests in. Unsealed fascia, soffit or cladding junctions turned up in 35%.

    What this means for your home

    Gaps around pipe penetrations, weep holes, eaves and service entries are how mice, cockroaches and ants get into a brand-new home. The NCC expects the building envelope to be reasonably sealed, and a 10 mm gap behind a tap or around a conduit is an open door. At handover these are quick to close with the right collar, mesh or sealant while the trades are still cycling through. Once you have moved in, the same gap means a pest-control bill and the frustration of a new house that already has visitors. We walk the full perimeter and the roof void looking for daylight — behind meter boxes, at the base of brickwork, around every penetration — and note each one so it is sealed before you are the one chasing it down. Each gap is photographed with its location so the builder can go straight to it rather than hunting. Sealing the envelope is also an energy and comfort issue, not just a pest one — the same gaps that let insects in let conditioned air out. Catching them at handover, while every trade is still cycling back for their own list, is the difference between a quick seal and a service call you pay for.

    The standard

    ABCB Housing Provisions 2022, 7.5.7 (cladding clearance to ground)